Differential scanning calorimeter YND-B1
Conforming the following standards:
GB/T 19466.2- 2009/ISO 11357-2:1999 GB/T 19466.3- 2009/ISO 11357-3:1999
GB/T 19466.6- 2009/ISO 11357-6:1999
Features:
l New sensor sample support, fully closed structure design, prevent items from falling into the furnace body.
l Built-in 10.8-inch computer, no additional computer, integrated equipment; The display is rich in information, including setting temperature, sample temperature, oxygen flow rate, nitrogen flow rate, differential heat signal, various switching states, etc.
l The right side of the instrument is equipped with standard four USB interfaces, which are convenient for users to connect external devices such as mouse, keyboard, printer and USB flash drive, and convenient for users to use.
l Pre-installed software, reduce computer adaptability problems, reduce due to the replacement of the use of the computer, installation drive error caused by the connection problems.
l Windows 10 system is equipped with 32GB capacity and 2GB system memory. Data can be stored inside the instrument without u-disk transfer. The touch screen and mouse button can be used for operation
l The furnace structure is compact, and the rate of rising and cooling is adjustable.
l The installation process is improved, and the mechanical fixation method is adopted to completely avoid the contamination of the internal colloidal of the furnace to the differential heat signal.
l The furnace is heated by heating wire, compact structure and small size.
l The double temperature probe ensures the high repeatability of the sample temperature measurement, and adopts the special temperature control technology to control the temperature of the furnace wall to set the temperature of the sample.
l The gas flow meter automatically switches between two channels of gas, with fast switching speed and short stable time.
l Standard sample is provided for easy adjustment of temperature coefficient.
l Software support each resolution screen, automatically adjust the computer screen size curve display mode. Support laptop, desktop; Support Win2000, XP, VISTA, WIN7, WIN8, WIN10 and other operating systems.
l Support user edit device operation mode according to actual needs to achieve full automation of measurement steps. The software provides dozens of instructions, and users can flexibly combine and save each instruction according to their own measurement steps. Complex operations are reduced to one-click operations.
Parameters:
1. Temperature range: RT-500℃
2. Temperature resolution:0.01℃
3. Heating rate: 0.1~80℃/min
4. Cooling rate: 0.1~30℃/min
5. Constant temperature: RT-500℃
6. Duration of constant temperature: The duration is recommended to be less than 24 hours.
7. Temperature control mode: Constant temperature rise, constant temperature
8. DSC range: 0~±500mW
9. DSC resolution: 0.01mW
10. DSC sensitivity: 0.01mW
11. Working power: AC 220V 50Hz 300W or other
12. Atmosphere control gas: Two-channel gas control by automatic controlled (e.g. nitrogen and oxygen)
13. Gas flow:0-200mL/min
14. Gas pressure:0.2MPa
15. Gas flow accuracy: 0.2mL/min
16. Crucible: Aluminium crucible Φ6.6*3mm (Diameter * High)
17. Calibration standard: with standard material (indium, tin, zinc), users can adjust the temperature and enthalpy value coefficient by themselvesb
18. Data interface: Standard USB interface
19. Display mode: 10.8-inch touch computer
21. Output mode: computer and printer
22. Fully closed support structure design, prevent items falling into the furnace body, pollution of the furnace body, reduce the maintenance rate