products

  • DMS5-340M LCD Strong Magnetic Heating Magnetic Stirrer with Timer

    DMS5-340M LCD Strong Magnetic Heating Magnetic Stirrer with Timer

    • Ceramic-coated aluminum plate, with strong corrosion resistance and easy to clean.
    • Corrosion-resistant full metal casing with excellent heat dissipation performance and reliable fire protection capabilities.
    • Selected high-temperature resistant strong magnetic stirrers, providing powerful stirring force, suitable for mixing viscous liquids.
    • Strong magnetic field, ideal for mixing viscous samples.
    • High protection level: IP42.
    • Heating modes:

    A: Rapid heating mode

    B: Standard heating mode

    C: Stable heating mode

    • To meet different customer needs.
    • Safety lock to prevent accidental changes in operating status.
    • Buzzer: When the machine malfunctions or the countdown for the timing function ends, the buzzer emits a “beep” sound to alert the user.
    • Residual heat warning: When the plate temperature exceeds 50°C, heating will be automatically turned off, and the display will show a flashing “HOT” warning. Even when the power is turned off, the “HOT” warning will continue flashing on the display, alerting the user of the high temperature.
    • Two independent safety circuits continuously monitor the device. In case of overheating, sensor malfunction, or system error, the machine will stop heating. If a short circuit occurs, the power will be automatically cut off, ensuring the operator’s safety.
    • DC brushless motor: Spark-free, long lifespan, low noise, maintenance-free, and smooth operation.
    • LCD display shows set and real-time values for speed, time, and temperature, offering clear and intuitive readings.
    • The timer function is available with a range of 1 minute to 99 hours and 59 minutes. Once the countdown ends, heating will stop, but stirring will continue to avoid thermal damage to the sample.
    • Remote control function is available, allowing the device to be connected to a computer.
    • The device comes with a variety of accessories, making it suitable for chemical synthesis laboratories in universities, research institutes, and enterprises.
    • Safety temperature can be set.
  • DMS4-550 LCD Glass Ceramic Heating Magnetic Stirrer with Timer

    DMS4-550 LCD Glass Ceramic Heating Magnetic Stirrer with Timer

    • The ceramic-coated plate offers excellent corrosion resistance, capable of withstanding strong acids, strong alkalis, and high temperatures. It is easy to clean spilled solvents, oils, or other contaminants.
    • The corrosion-resistant full metal housing provides good heat dissipation and reliable fire protection.
    • The efficient drainage platform and raised waterproof edge prevent liquids from entering the machine and corroding internal electronic components.
    • Selected high-temperature resistant strong magnets provide powerful stirring force, suitable for mixing viscous liquids.
    • The safety lock prevents accidental changes to the operating status.
    • Buzzer: When a fault occurs or the timer countdown ends, the buzzer emits a “beep beep beep” alert sound.
    • Residual heat warning function: When the plate temperature exceeds 50°C, heating is turned off and the screen displays a flashing “HOT” warning. Even after power-off, the display continues to flash “HOT” to indicate high temperature.
    • Dual independent safety circuits continuously monitor the device. In the event of overheating or sensor failure, the machine shows an error and stops heating. If a short circuit occurs, the power is automatically cut off to ensure operator safety.
    • The brushless DC motor is spark-free, long-lasting, low-noise, maintenance-free, and runs smoothly.
    • The LCD displays both set and real-time values for speed, time, and temperature, providing clear and intuitive readouts.
    • Timer function: Settable from 1 minute to 99 hours 59 minutes. When the countdown ends, heating stops but stirring continues, preventing thermal damage to samples.
    • Remote control function is available, allowing connection to a computer.
    • Safety temperature can be preset.
  • DMS5-280/120 LED Heating Magnetic Stirrer

    DMS5-280/120 LED Heating Magnetic Stirrer

    • Equipped with an LED display, it accurately shows temperature and speed, providing real-time data during experiments and ensuring easy operation.
    • The speed runs stably, adapting to various experimental requirements and delivering uniform stirring results.
    • Temperature is adjustable, reaching up to 280°C(DMS5-280), suitable for a variety of heating experiments, with precise temperature control.
    • Supports dual temperature sensors, accurately monitoring the heating plate and solution temperatures, further enhancing heating efficiency and safety.
    • Overheat protection function: If the heating plate temperature exceeds 50°C, the screen automatically displays a flashing “HOT” warning. Even when powered off, the warning remains visible, enhancing safety during use.
    • Features a ceramic-coated heating plate, offering excellent heat conductivity, corrosion resistance, and wear resistance, making it suitable for long-term high-temperature use.
    • Equipped with a touch panel, it provides simple and intuitive operation, improving user experience. Its compact design makes it easy to operate and store in laboratory environments.
    • Powerful magnetic stirring performance, ensuring uniform stirring of various solutions to meet diverse experimental needs.
  • MS-H380-F100/250/500/1000/2000 LCD Digital Magnetic Stirrer Heating Mantle

    MS-H380-F100/250/500/1000/2000 LCD Digital Magnetic Stirrer Heating Mantle

    • Data communication:RS232 interface.
    • Buzzer alert: countdown timer end is indicated by a”beep-beep-beep” sound.
    • Timer function: time range from 1 minute to 99 hours 59 minutes. Heating stops when countdown ends, butstirring continues to avoid sample damage from residual heat.
    • Operating status indicator lights:Green is Reached to set temperature; Blinking green is heating to settemperature; Red is fault/alarm.

    Application Scenarios

    Organic synthesis,polymerization, distillation and purification,sample dissolution and extraction, sample pretreatment before analysis, catalytic reaction kinetics research, etc,

    Target Customers

    Technicians in chemical, biological, pharmaceutical, and materials enterprises,researchers in universities and research institutes, quality control analysts in laboratories related to pharmaceuticals, food.environmental protection, etc.