products

  • Thermogravimetric analysis TGA-1550C

    Thermogravimetric analysis TGA-1550C

    Consistent but not limited to the following national standards: l GB∕T 14837-2018 Rubber and rubber products; l JB/T 6856-1993 Thermogravimetric – differential thermal analyzer; l GB/T 36246-2018 2018 Primary and middle school synthetic material surface course; l YB/T 4328 Test method for free calcium oxide in steel slag; l GB/T 2951.41-2008 General test method for cable and optical cable insulation and sheath materials; Features: l Industrial level widescreen touch structure is r...
  • Thermogravimetric analysis TGA-1450C

    Thermogravimetric analysis TGA-1450C

    Consistent but not limited to the following national standards: l GB∕T 14837-2018 Rubber and rubber products; l JB/T 6856-1993 Thermogravimetric – differential thermal analyzer; l GB/T 36246-2018 2018 Primary and middle school synthetic material surface course; l YB/T 4328 Test method for free calcium oxide in steel slag; l GB/T 2951.41-2008 General test method for cable and optical cable insulation and sheath materials; Features: l Industrial level widescreen touch structure is r...
  • Thermogravimetric analysis TGA-1250C

    Thermogravimetric analysis TGA-1250C

    Consistent but not limited to the following national standards: l GB∕T 14837-2018 Rubber and rubber products; l JB/T 6856-1993 Thermogravimetric – differential thermal analyzer; l GB/T 36246-2018 2018 Primary and middle school synthetic material surface course; l YB/T 4328 Test method for free calcium oxide in steel slag; l GB/T 2951.41-2008 General test method for cable and optical cable insulation and sheath materials; Features: l Industrial level widescreen touch structure is r...
  • Thermogravimetric analysis TGA-1000C

    Thermogravimetric analysis TGA-1000C

    Consistent but not limited to the following national standards: l GB∕T 14837-2018 Rubber and rubber products; l JB/T 6856-1993 Thermogravimetric – differential thermal analyzer; l GB/T 36246-2018 2018 Primary and middle school synthetic material surface course; l YB/T 4328 Test method for free calcium oxide in steel slag; l GB/T 2951.41-2008 General test method for cable and optical cable insulation and sheath materials; Features: l Industrial level widescreen touch structure is r...
  • Thermogravimetric analysis TGA-1550B

    Thermogravimetric analysis TGA-1550B

    Features: l Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, various switch states, etc. l Use the gigabit network line communication interface, the universality is strong, the communication is reliable without interruption, supports the self-recovery connection function. l The furnace body is compact, temperature rise and fall speed adjustable. l Water bath and h...
  • Thermogravimetric analysis TGA-1450B

    Thermogravimetric analysis TGA-1450B

    Features: l Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, various switch states, etc. l Use the gigabit network line communication interface, the universality is strong, the communication is reliable without interruption, supports the self-recovery connection function. l The furnace body is compact, temperature rise and fall speed adjustable. l Water bath and h...
  • Thermogravimetric analysis TGA-1000B

    Thermogravimetric analysis TGA-1000B

    Features: l Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, various switch states, etc. l Use the gigabit network line communication interface, the universality is strong, the communication is reliable without interruption, supports the self-recovery connection function. l The furnace body is compact, temperature rise and fall speed adjustable. l Water bath and h...
  • Thermogravimetric analysis TGA-1250B

    Thermogravimetric analysis TGA-1250B

    Features: l Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, various switch states, etc. l Use the gigabit network line communication interface, the universality is strong, the communication is reliable without interruption, supports the self-recovery connection function. l The furnace body is compact, temperature rise and fall speed adjustable. l Water bath and h...
  • Differential scanning calorimeter DSC-OM2

    Differential scanning calorimeter DSC-OM2

    Summary: The DSC is a touch screen type, specially testing polymer material oxidation induction period test, customer one-key operation, software automatic operation. Support one experiment to measure 2 samples Conforming the following standards: GB/T 19466.6- 2009/ISO 11357-6:1999 Features: l Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature, oxygen flow, nitrogen flow, differential thermal signal, various switch states, et...
  • Differential scanning calorimeter DSC-OM4

    Differential scanning calorimeter DSC-OM4

    Summary: One-key operation, automatic operation, isothermal Oxidative induction time special equipment The DSC is a touch screen type, specially testing polymer material oxidation induction period test, customer one-key operation, software automatic operation. Support one experiment to measure 4 samples Conforming the following standards: GB/T 19466.6- 2009/ISO 11357-3:1999 No.6 Features: l Industrial level widescreen touch structure is rich in information, including setting temperature, s...
  • Differential scanning calorimeter DSC-BM2

    Differential scanning calorimeter DSC-BM2

    Summary: The DSC is a touch screen type, specially testing polymer material oxidation induction period test, customer one-key operation, software automatic operation. Support one experiment to measure 2 samples Conforming the following standards: GB/T 19466.2- 2009/ISO 11357-2:1999 GB/T 19466.3- 2009/ISO 11357-3:1999 GB/T 19466.6- 2009/ISO 11357-6:1999 Features: l Industrial level widescreen touch structure is rich in information, including setting temperature, sample temperature, oxygen flo...
  • Differential scanning calorimeter YND-OM2

    Differential scanning calorimeter YND-OM2

    One-key operation, automatic operation, isothermal Oxidative induction time special equipment Conforming the following standards: GB/T 19466.6- 2009/ISO 11357-6:1999 Support one experiment to measure 2 samples Features: l New sensor sample support, fully closed structure design, prevent items from falling into the furnace body. l Support to measure two samples at the same time, the efficiency is greatly improved by 2 times. It is very convenient to measure multiple samples at the same furna...