Y09-3016 Handheld Air Dust Particle Counter
The instrument can simultaneously measure the number of dust particles with multiple particle sizes in one sampling. and this product has been widely used for cleanroom testing in electronic production enterprises; On site inspection and leak detection of filters; It can monitor biosafety, HVAC systems, computer rooms, beverage packaging environments, drug and medical device production environments, hospital clean operating rooms, automotive spraying environments, microelectronics, biochemica... -
FKC-V on-line Air sampler
The sampler consists of two parts: the fan box and the sampling head. The porous sampling head is made of stainless steel 316L or alumina, and there are 397 0.7mm microholes on it. Optional bottom bracket to meet different sampling heights High performance fans meet higher impact speeds, ensuring the capture efficiency of smaller particle size microorganisms Volume 100 L/min Sampling volume Settable Petri dish specifications (ø90 x 15) mm Power supply DC24V, 5A Sampling head Micropores, alumi... -
FKC-100S Air Sampler (Audit Trail)
The sampling is direct, and the wind speed at the collecting head is basically consistent with the wind speed in the clean room, which can accurately reflect the concentration of microorganisms in the clean room. During sampling, air carrying dust bacteria passes through the micropores at high speed and is uniformly hit the AGAR surface in the petri dish. The instrument has a high degree of intelligent integration, so the operation is simple and the performance is stable. The collection head ... -
Air Sampler FX-100ST
The air suction flow rate of FX-100ST is 100 L/min. Each collection cycle can collect up to 9999 liters. This performance enables sampling to be carried out under strict requirements for monitoring sterile and clean rooms. The impact speed (the speed at which microorganisms in the air impact the surface of agar) is approximately 10 m/s, equivalent to level 5 of the Andersen sampler. Note: FX-100ST reference standard: ISO 14698-1/2, GMP, GB16293-2010 The sampling speed is 100L/min ±2.5%, and t... -
BM-100 Planktonic bacteria sampler calibrator
Air bacteria sampler calibrator Mainly used to calibrate all microporous plankton samplers. The sampler flow can be measured quickly and accurately without increasing the load on the sampler, causing large deviations in the flow before and after the test. The accuracy of the data can be comparable to that of the DA-100NT Executive standard for BM-100: JJG198-1994. High precision ±2.5% Flow range 0-200L/min Appearance diameter 110mm, height 87mm Operation Method One-touch operation you can use... -
FKC-III Air Sampler
The FKC-III type planktonic bacteria sampler is an efficient porous suction microbial sampler. It is designed based on the theory of isokinetic sampling, with direct sampling. The wind speed at the collection head is basically consistent with the wind speed in the clean room, accurately reflecting the concentration of microorganisms in the clean room. During sampling, the air carrying dust bacteria passes through the micropores at high speed and is evenly impacted on the agar surface inside the culture dish.
-
Air sampler FKC-2
Product Features The sampling head has a total of 397holes, with an impact velocity of 10.8m/s and a diameter of 0.7mm micropores, reducing bacterial overlap and microbial count errors. The sampling amount can be set arbitrarily from1-9999L Sampling delay and sampling interval time can be set. Color touch screen displays parameters such as sampling amount, sampling delay, sampling interval, sampling quantity, etc. Sample quantity, sampling time, and other parameters are stored on a page by pa... -
Biological Air sampler FKC-1
FKC-1 Microbial air sampler is a highly porous inhaled dust sampler. It according to the design theory of isokinetic sampling, the sampling directly, collecting head wind speed and clean indoor air velocity is basically the same, can more accurately reflect the clean indoor microbial concentrations. When sampling, with dust air speed through a microporous, is uniformly impinging on the culture dish on the agar surface; these living microorganisms on the surface of the agar to obtain nutrition uniform and sufficient, in the training process, fast dynamic process of water, high speed growth, resulting in faster that results
-
High efficiency Air Supply Port
The high efficiency air supply outlet is the ideal terminal filtration device for thousand-grade thousand-grade, and hundred-grade purification air conditioning system, which can be widely used in the purification air conditioning system of medicine, health, electronics, chemical and other industries. The high efficiency air supply outlet is used as a terminal filtration device for the renovation and construcion of 1000-300000 clean rooms at alleveis, and is a key equipment to meet the purification requirements. The high efficiency air supply por includes plenum, diffuser plate, high efficiency filter, and the interface with the air pipe can be top or side connection
-
FFU laminar flow air supply unit
Laminar flow air supply unit is widely used in clean room, clean laminar flow belt, clean shed and so on because of its small size, easy installation and modular connection.
-
Negative Weighing Booth
The weighing booth is a partial purification equipment used in pharmaceutical, microbiological research, and scientific laboratories. It provides a vertical unidirectional airflow, with some clean air circulating in the work area and some discharged to nearby areas, causing negative pressure in the work area and preventing cross contamination. It is used to ensure a high cleanliness environment in the work area
-
Clean Laminar Flow Booth
Clean laminar flow hood is a new type of structural laminar flow hood designed based on the actual situation of clean rooms, suitable for industries such as electronics, precision instruments, medical and food. It can be used by lifting or scaffolding.